TRADE THEORY MONTHLY TEST (ITISKILL87618G)

Question 1 1 Marks
How to safe guard the hands while handling glass wool?
A
Wearing goggles
B
Wearing gloves
C
Using mask
D
Using shoes
Question 2 1 Marks
How to prevent the small pieces of glass wool affecting the eyes?
A
Wearing goggles
B
Wearing gloves
C
Using mask
D
Using shoes
Question 3 1 Marks
Which component belongs to indoor unit of split AC?
A
Compressor
B
Condenser
C
Evaporator
D
Drier
Question 4 1 Marks
Which control opens the compressor motor circuit in the event of continuous overload?
A
Thermostat
B
Fusible plug
C
Bimetal strip
D
Spring loaded relief valve
Question 5 1 Marks
Which motor is used to drive the blower of indoor unit in ductable split air conditioners?
A
Shaded pole motor
B
Permanent split capacitor motor
C
Three phase induction motor
D
Capacitor start capacitor run motor
Question 6 1 Marks
Which fan is used in condensing unit of ductable split air conditioner?
A
Forward curved fan
B
Centrifugal fan
C
Propeller fan
D
Radial fan
Question 7 1 Marks
Which component belongs to outdoor unit of split AC?
A
Blower
B
Air filter
C
Compressor
D
Evaporator coil
Question 8 1 Marks
Which material is used to make ducts in split AC?
A
Thermocole
B
GI sheet
C
Wood
D
Fibre
Question 9 1 Marks
Which type of switch is used to control the room air temperature in split AC?
A
Over load protector
B
Thermostat switch
C
Manual switch
D
Thermal relay
Question 10 1 Marks
Which type fan blade is used with out door unit of split AC?
A
Vane
B
Guide vane
C
Propeller
D
Centrifugal
Question 11 1 Marks
How many fan motors are used in split AC?
A
Two
B
Five
C
Four
D
Three
Question 12 1 Marks
Which type of fan blade is used with indoor unit?
A
Guide vane
B
Blower
C
Axial
D
Vane|
Question 13 1 Marks
Where the refrigerant is stored in split AC during pump down operation?
A
Accumulator
B
Compressor
C
Evaporator
D
Condenser
Question 14 1 Marks
Which horizontal distance is preferred between indoor and outdoor units in ductable split AC installation?
A
15 meters
B
12 meters
C
20 meters
D
25 meters
Question 15 1 Marks
Which process is done first in split AC for shifting from one place to another?
A
Flushing
B
Evacuation
C
Pump down
D
Vacuumisation
Question 16 1 Marks
Which fan motor speed is used with outdoor unit in split AC?
A
Single speed
B
Double speed
C
Triple speed
D
Five speed
Question 17 1 Marks
What is the function of starting capacitor in CSIR motor?
A
Gives initial torque
B
Gives running torque
C
Corrects power factor
D
Improves energy efficiency
Question 18 1 Marks
What is the advantage of periodical cleaning of air filter?
A
Decrease the volume of air handling
B
Increase the speed of fan motor
C
Decrease the cooling capacity
D
Increase the cooling capacity
Question 19 1 Marks
What tonnage capacity of split AC unit uses 150/200 MFD starting capacitor?
A
1 TR
B
1.5 TR
C
2.0 TR
D
2.5 TR
Question 20 1 Marks
Which valve helps to attend mechanical faults without wasting the gas in split AC?
A
Gate valve
B
Float valve
C
Service valve
D
Expansion valve
Question 21 1 Marks
Which is the mounting location of evaporator in ductable split unit?
A
Floor mounting
B
Wall mounting
C
Ceiling mounting
D
Roof mounting
Question 22 1 Marks
What is the function of remote control in split AC?
A
Humidity setting
B
Pressure setting
C
Drain water control
D
Transmits signal to operate AC
Question 23 1 Marks
What is the cause for noisy fan motor in outdoor unit of split AC?
A
Bearing worn out
B
Motor Burnt
C
Shaft struck
D
Blade bent
Question 24 1 Marks
How the pressure drop of refrigerant flow is minimised during installation of indoor and outdoor units in ductable split AC?
A
Pipe lines with more joints
B
With more horizontal distance
C
System pipes with minimum bends
D
Install units as far as possible
Question 25 1 Marks
What is the reason for poor condensation in split AC?
A
High ambient temperature
B
Low ambient temperature
C
Condenser tube leaky
D
Blower motor failure