Quiz Questions

Mock exam (ITISKILL76607U)

Question 1 1 Marks
Which type of compressor is used in window air conditioner?
A
Belt drive
B
Open type
C
Sealed type
D
Swash plate
Question 2 1 Marks
Which type of condenser is used in window air conditioner?
A
Fins and tube
B
Plate and tube
C
Plate and coil
D
Bare tube
Question 3 1 Marks
Which type of expansion valve is used in window air conditioner?
A
Capillary tube
B
Low side float valve
C
Automatic expansion valve
D
Thermostatic expansion valve
Question 4 1 Marks
Which type of evaporator is used in window air conditioner?
A
Bare tube
B
Plate and tube
C
Fins and plate
D
Fins and tube
Question 5 1 Marks
Which material is used for making fins of condenser in a window air conditioner?
A
Brass
B
Copper
C
Cast iron
D
Aluminium
Question 6 1 Marks
What is the cooling capacity of 0.5 TR in BTU / hr?
A
6000
B
12000
C
18000
D
24000
Question 7 1 Marks
1 Which control device is used to maintain the room air temperature?
A
OLP
B
Relay
C
Thermostat
D
Selector switch
Question 8 1 Marks
Which relay is used in capacitor start, capacitor run (CSR) compressor motor?
A
Voltage relay
B
Current relay
C
Thermal relay
D
Amperage relay
Question 9 1 Marks
Which safety device is used for compressor motor in window air conditioner?
A
Relay
B
Starting capacitor
C
Running capacitor
D
Over load protector
Question 10 1 Marks
Which part of window AC removes dust particles from the room air?
A
Strainer
B
Air filter
C
Filter drier
D
Dehydrator
Question 11 1 Marks
Which capacity of fan motor is used in 1Ton window air conditioner?
A
1/5 HP
B
1/10 HP
C
1/16 HP
D
1/20 HP
Question 12 1 Marks
Which capacitor is connected in series with starting winding of CSR motor during operation?
A
Fan capacitor|
B
Run capacitor
C
Start capacitor
D
No capacitor is connected
Question 13 1 Marks
What is the value of running capacitor used for 1.5 TR window air conditioner?
A
36 MFD
B
40 MFD
C
80 MFD
D
100 MFD
Question 14 1 Marks
What is the value of starting capacitor used for 1TR window air conditioner?
A
40 MFD
B
60 MFD
C
80 MFD
D
100 MFD
Question 15 1 Marks
What is the purpose of relay used in window air conditioner?
A
Disconnect the starting capacitor
B
Disconnect the running capacitor
C
Disconnect the fan capacitor
D
Disconnect the winding
Question 16 1 Marks
Which is increased by the fins of condenser tubes in window air conditioner?
A
Heat transfer rate
B
Power consumption
C
Discharge pressure
D
Refrigerant flow rate
Question 17 1 Marks
What is the remedy for the defective OLP in a window air conditioner?
A
Repair the OLP
B
Replace the OLP
C
Remove the parts
D
Repair the heater element
Question 18 1 Marks
What is the cooling capacity of 1 TR in K Cal / hr?
A
3000
B
4000
C
5000
D
6000
Question 19 1 Marks
Where the relay coil is internally connected in voltage relay?
A
Across 1 and 2
B
Across 5 and 1
C
Across 5 and 2
D
Across 2 and 4
Question 20 1 Marks
Which winding of compressor motor is directly connected across voltage relay coil?
A
Main winding
B
Starting winding
C
Running winding
D
Auxiliary winding
Question 21 1 Marks
What is the reason for excessive frost on evaporator coil in window AC?
A
Evaporator fins not blocked by dust
B
Blower rotating at higher speed
C
Air filter blocked completely
D
More air circulation in evaporator
Question 22 1 Marks
What is the reason for Very high condenser temperature in a window air conditioner?
A
Water splashes condenser
B
More air flows into the condenser
C
Fan motor working in good condition
D
Dust accumulated in the condenser fins
Question 23 1 Marks
How to neutralise the concentration of leaked ammonia from air
A
Recover ammonia from air
B
Spraying a lot of water
C
Shut down the plant
D
Spray Hydrochloric acid
Question 24 1 Marks
What is the reason for the compressor does not start but the fan motor works normally in window AC?
A
Defective blower
B
Defective fan motor
C
Defective fan capacitor
D
Defective compressor motor
Question 25 1 Marks
Which device is used to exhaust the room air in window AC?
A
Damper
B
Air filter
C
Filter drier
D
Air washer
Question 26 1 Marks
What is the area of room cooled by 1ton window air conditioner?
A
5000 sq.ft
B
2000 sq.ft
C
1000 sq.ft
D
3000 sq.ft
Question 27 1 Marks
Where the filter drier is installed in window AC refrigerant circuit?
A
Discharge line
B
Suction line
C
Service line
D
Liquid line
Question 28 1 Marks
Which winding has high inductance value in CSR compressor motor?
A
Common winding
B
Running winding
C
Starting winding
D
Auxiliary winding
Question 29 1 Marks
What is the reason for the compressor motor burn out in a window air conditioner?
A
Defective fan capacitor
B
Defective fan motor
C
Defective blower
D
Defective OLP
Question 30 1 Marks
What is the purpose of operating the fan motor first and then the compressor motor in Air conditioners?
A
Cool the coils first by fan
B
Cool the compressor by fan
C
Minimise the noise of motors
D
Stop the high starting current by both motors
Question 31 1 Marks
What is the effect of sensing higher
temperature by thermistor NTC?
A
Resistance increases
B
Resistance decreases
C
Resistance becomes zero
D
Resistance becomes infinity
Question 32 1 Marks
Where the normally closed contacts are internally connected in voltage relay?
A
Across 1 and 5
B
Across 2 and 5
C
Across 1 and 2
D
Across 2 and 4
Question 33 1 Marks
What is the reason for Compressor does not start ?
A
Defective fresh air damper
B
Defective oscillation motor
C
Defective fan motor
D
Defective OLP
Question 34 1 Marks
What is the remedy to remove moisture from the window AC system?
A
Over gas charge in the system
B
Evacuate the system deeply
C
Clean the evaporator fins
D
Clean the condenser fins
Question 35 1 Marks
What is the capacity of compressor motor used in 1Ton window air conditioner?
A
0.50 HP
B
0.75 HP
C
0.95 HP
D
1.00 HP
Question 36 1 Marks
Which type of fan motor is used in window air conditioner?
A
Three phase single shaft motor
B
Single phase single shaft motor
C
Three phase double end shaft motor
D
Single phase double end shaft motor
Question 37 1 Marks
What is the cause of reduced supply air throw though air filter is clean in window AC?
A
No frost in the evaporator
B
Frost accumulated in the evaporator
C
Dust accumulated in the condenser
D
No dust accumulated in the evaporator
Question 38 1 Marks
What is the value of starting capacitor used for 1.5TR capacity window air conditioner?
A
40 to 60 MFD
B
80 to 100 MFD
C
130 to 150 MFD
D
150 to 160 MFD
Question 39 1 Marks
Which stabilizer capacity is used for 1 Ton window air conditioner?
A
2 KVA
B
3 KVA
C
4 KVA
D
5 KVA
Question 40 1 Marks
Which is indicated by the arrow mark on filter drier component?
A
Flow direction of air
B
Position of capillary tube
C
Flow direction of refrigerant
D
Arrangement of desiccant and filter