Quiz Questions

ITI Quiz - 10-Jun-2026 01:54 PM (ITISKILL4472PW)

Question 1 1 Marks
Which type of compressor is used in window air conditioner?
A
Belt drive
B
Open type
C
Sealed type
D
Swash plate
Question 2 1 Marks
Which type of condenser is used in window air conditioner?
A
Fins and tube
B
Plate and tube
C
Plate and coil
D
Bare tube
Question 3 1 Marks
Which type of expansion valve is used in window air conditioner?
A
Capillary tube
B
Low side float valve
C
Automatic expansion valve
D
Thermostatic expansion valve
Question 4 1 Marks
Which material is used for making fins of condenser in a window air conditioner?
A
Brass
B
Copper
C
Cast iron
D
Aluminium
Question 5 1 Marks
Which relay is used in capacitor start, capacitor run (CSR) compressor motor?
A
Voltage relay
B
Current relay
C
Thermal relay
D
Amperage relay
Question 6 1 Marks
Which capacitor is connected in series with starting winding of CSR motor during operation?
A
Fan capacitor|
B
Run capacitor
C
Start capacitor
D
No capacitor is connected
Question 7 1 Marks
What is the value of running capacitor used for 1.5 TR window air conditioner?
A
36 MFD
B
40 MFD
C
80 MFD
D
100 MFD
Question 8 1 Marks
What is the purpose of relay used in window air conditioner?
A
Disconnect the starting capacitor
B
Disconnect the running capacitor
C
Disconnect the fan capacitor
D
Disconnect the winding
Question 9 1 Marks
Which is increased by the fins of condenser tubes in window air conditioner?
A
Heat transfer rate
B
Power consumption
C
Discharge pressure
D
Refrigerant flow rate
Question 10 1 Marks
Which is indicated by the arrow mark on filter drier component?
A
Flow direction of air
B
Position of capillary tube
C
Flow direction of refrigerant
D
Arrangement of desiccant and filter
Question 11 1 Marks
Which device is used to exhaust the room air in window AC?
A
Damper
B
Air filter
C
Filter drier
D
Air washer
Question 12 1 Marks
Where the filter drier is installed in window AC refrigerant circuit?
A
Discharge line
B
Suction line
C
Service line
D
Liquid line
Question 13 1 Marks
Where the relay coil is internally connected in voltage relay?
A
Across 1 and 2
B
Across 5 and 1
C
Across 5 and 2
D
Across 2 and 4
Question 14 1 Marks
What is the remedy to remove moisture from the window AC system?
A
Over gas charge in the system
B
Evacuate the system deeply
C
Clean the evaporator fins
D
Clean the condenser fins
Question 15 1 Marks
What is the cause of reduced supply air throw though air filter is clean in window AC?
A
No frost in the evaporator
B
Frost accumulated in the evaporator
C
Dust accumulated in the condenser
D
No dust accumulated in the evaporator